Troubleshooting a MaxxFan Roof Vent Fan That Has Stopped Working
Updated 08/13/2020 | Published 05/11/2018 >
Products Featured in This Question
Question:
Our fan quit working, no power at all. Is there a fuse somewhere on the fan?
asked by: Patti S
Expert Reply:
Roof vents with fans like the MaxxFan Roof Vent w/ 12V Fan # MA00-04000K do not have a fuse anywhere in the fan itself. You will want to use a circuit tester like # PTW2993 to see if there is power getting to the fan. If it was installed by the manufacturer, there may be a circuit breaker that it is attached to, but most of the time they are directly wired to the 12V power.
If there is power going to the switch, you may simply need to replace the switch and not the entire assembly. Depending on what vent you have, there may not be an option other than to replace the entire unit.
Product Page this Question was Asked From
MaxxFan Plus Roof Vent w/ 12V Fan and Thermostat - Manual Lift - 10 Speed - White
- RV Vents and Fans
- Vent
- Roof Vent
- Manual Lift
- 12V Fan
- Reversible Fan
- Plastic
- White
- MAXXAIR
more information >
Featured Help Information
Instructions
Miscellaneous Media
Continue Researching
- Video: The Low-Down on the Replacement Motor for Stromberg Carlson Electric Landing Gear
- Shop: Replacement Motor for Stromberg Carlson Electric Landing Gear - 5,500 lbs
- Search Results: landing gear gearbox
- Shop: Stromberg Carlson Electric Landing Gear Set - Weld On - 34-7/8" Lift - 6,500 lbs
- Shop: Replacement Printed Circuit Board and Switch for MaxxFan Roof Vents
- Shop: Replacement Handheld Remote for MaxxAir Roof Vent Intake/Exhaust Fans - Qty 1
- Search Results: maxxair circuit board
- Shop: Hook Probe Circuit Tester
- Q&A: Troubleshooting MaxxAir MaxxFan 12V Fan-Powered Trailer Roof Vent That Beeps
- Q&A: Troubleshooting MaxxAir Vent Fan that Won't Turn On and Rain Sensor Light On
- Q&A: Solution to Replace Remote on Fan-Tastic Vent 6600R-417 Without Replacing Entire Unit
- Q&A: Troubleshooting Remote of Fan-Tastic Roof Vent 7350 Not Operating Fan
- Shop: Fastway e2 Weight Distribution w/ 2-Point Sway Control - Trunnion - 10,000 lbs GTW, 1,000 lbs TW
- Shop: MaxxFan Plus Roof Vent w/ 12V Fan, Thermostat, and Remote - Powered Lift - 10 Speed - Smoke
- Q&A: Parts Needed to Install Brake Controller 2024 Mercedes Sprinter 3500
- Shop: Brake Controller
- Shop: Trailer Wiring
- Article: Trailer Wiring Diagrams
- Shop: Trailer Hitch
- Q&A: What is the Difference Between a Class II and a Class III Hitch?
- Search Results: trailer hitch
- Q&A: Lug Nut Torque Chart for Trailer Wheels
- Search Results: trailer wiring
- Article: Brake Controller 7- and 4-Way Installation Kit (ETBC7)
- Video: Redarc Tow-Pro Liberty Brake Controller Review RED24FR
- Search Results: trailer jack
- Article: Wiring Trailer Lights with a 7-Way Plug (It's Easier Than You Think)
- Shop: Suspension Enhancement
- Article: How to Measure for Trailer Hitch Drop
- Search Results: trailer tires and wheels



John H.
6/15/2020
My Maxxfan 4000K runs on low and medium speed. When i put it on high speed It kicks out and starts beeping and the green light comes on. I have to depower the unit to restart it (the off switch does not work to depower the unit). I checked the wiring and it seems to be installed & wired correctly. I ordered a new circuit board from eTrailer and replaced it. It continues to kick out on high speed. Any thoughts?