Hey Andrew! Yes, Furrion does have a Chill Cube model with a heat pump. This was actually just released for aftermarket sale. You will need a complete system to make the switch, new R32 units aren't backwards compatible with old R410A systems.…
Hello Sam; that is a great question! I reached out to Furrion and you will be able to use the Furrion Chill Cube #FR69TD (white) or #FR49TD (black) with your furnace. However, the remote is not capable of operating the furnace at this time. Also, we…
Hey Neil. The 18,000 Btu Furrion Chill Cube RV Air Conditioner item #LC34DX fits a 14-1/4" x 14-1/4" cutout which is pretty standard on RV's. If you meant to write Dometic instead of domestic then yes it'll fit in your existing…
Hey Jon; I was actually just talking to Furrion about heat options for the Chill Cube yesterday (1/21/2025). At this time, the only way to have heat with this unit is through a furnace on a ducted setup. The Furrion Chill Cube RV AC w/ Air…
Hey Mike! The Advent Air RV Air Conditioner #ADV74QR is only designed to work with an R32 setup. Your old unit is going to be R410A, so the old components won't be compatible. Since everything moved to R32 last year due to EPA regulations a…
Hey Kenny, welcome back! The reason for that note is because all of the new systems since 2025 use R32 refrigerant due to EPA regulations. Any 2024 and older systems use R410A and their parts are not compatible with the R32 units. It doesn't mean…
Hi JD; the Furrion Chill Cube #FR49TD air distribution box has a vent on it you can open and close. See the picture attached below. When it is closed it forces more of the air through the ducted system. Assuming you have a ducted system you will need…
Hi Collin, welcome back! The most economical replacement is going to be from Advent Air. You will need a complete system since everything moved to R32 refrigerant. If your upgraded thermostat is R32 compatible, or a smart thermostat that got a…
Hey Doug welcome back! To replace your 15,000 btu Dometic Duo-Therm, I recommend the Advent Air RV Air Conditioner System item #ADV99QR in white or item #ADV69QR in black for a ducted setup. The Advent Air RV Air Conditioner System item #ADV39QR in…
Hey Keith! I can definitely help you find a replacement for your Dometic Duo Therm. However, you're going to have to replace the thermostat and air distribution box as well. Your current setup is for R410A and everything switched to R32 last year…
Hey Arkadius, welcome back! Yes, the ducted version of the Chill Cube comes with a remote. However, you're going to need the complete system for a replacement. You can choose from the following based on color: -Furrion Chill Cube RV Air…
Hey Kyle! That is correct. The Coleman-Mach Mach-C Everest has variable-speed cooling and an inverter-driven compressor. However, the Mach-C Everest uses a traditional wall thermostat instead of a remote control. It also works with both ducted and…
Go all-in and simplify your swap with a complete ac system. Pick ducted or ductless, and use the air distribution box to push more air through your ducts when you want it. If you're moving to an R32 unit, you need the full system since it isn't backward compatible with old R410A setups, and add a wall thermostat if you want it to run your furnace while the remote handles AC functions.
Yes—new R32 units aren't backwards compatible with old R410A systems, so choose a complete AC system. Confirm whether your RV is ducted or ductless before ordering. Plan to use the included controls, since older components may not communicate.
It uses an air distribution box with a vent you can open or close. Closing the vent sends more air through the ducts. Verify your RV is ducted and the air box matches your ceiling opening.
Installation is doable for a DIYer. One installer took about 4 hours with no prior experience. The rooftop unit is close to 80 lbs, so get help lifting it. Follow the instructions and torque retaining bolts to 40 inch pounds. Plan a hot-weather test after install.
It can, but plan the controls. Some systems use a remote that doesn't run a furnace; keep your furnace on its existing wall thermostat or add a wall thermostat with furnace terminals. Provide a constant 12 volt supply and ground to the thermostat. If the main unit lacks 120v, an error may display outside HEAT mode. Set dip switch 2 ON for gas furnace.