What Is The Difference Between A Check Valve And By-Pass Kit
Updated 07/05/2017 | Published 07/02/2017 >
Products Featured in This Question
Question:
Could the failure of this valve be the reason I still got anti-freeze in my hot water tank even though I had the By-Pass valve in the By-Pass position when winterizing my 2004 Monaco Knight coach ?
asked by: Gene
Helpful Expert Reply:
Antifreeze leaking into the water heater could be remotely caused by a bad check valve, however, this would all depend on the location of the check valve. Generally speaking, there are only 2 check valves installed in the plumbing system for an RV. There is one coming from the city water inlet and one on the fresh water tank. A check valve such as the Valterra Check Valve part # P23415LFVP is designed to prevent water from backfeeding into your freshwater tank or city water connection and help pressurize the lines. In most RV plumbing applications, the cold water line running to the RV's water heater is redirected to the hot line using a bypass valve such as the Valterra EZ Turn RV Water Heater By-Pass Kit part # P23505LFVP. If the water heater has antifreeze in it while the bypass is open, you more than likely have a bad bypass than a faulty check valve.
If you can tell me as to where the check valve is located, I can provide further information for you.
Product Page this Question was Asked From
Valterra Check Valve for RV Fresh Water Systems - Dual 1/2" MPT - Brass
- RV Fresh Water
- Prevent Backflow
- Valves
- Brass
- Water Heater Check Valve
- 1/2 Inch
- Threaded
- Valterra
more information >
Continue Researching
- Shop: Valterra RV Water Heater Bypass Kit for 10 Gallon Tanks - Dual Valve - Permanent
- Shop: Valterra RV Water Heater Bypass Kit for 10 Gallon Tanks - Single Valve - Permanent
- Shop: Valterra RV Water Heater Bypass Kit for 6 Gallon Tanks - Dual Valve - Permanent
- Video: Review of WFCO RV Power Converter - Converter Only - WF98FR
- Shop: 3-Way RV Water Heater Bypass Valve - 1/2" MPT x 1/2" MPT x 1/2" FPT
- Shop: B&B RV Hot Water Tank Bypass Diverter Valve and Plate Assembly - Red
- Shop: WFCO Auto-Detect RV Converter Charger - Deck Mount - 12V - 65 Amp
- Shop: WFCO Auto-Detect RV Converter Charger - Deck Mount - 12V - 55 Amp
- Q&A: Maximum Air Pressure of Dexstar 16 x 6 Trailer Wheel
- Video: Breaking Down the Valterra Check Valve for RV Fresh Water Systems
- Video: B and B RV Hot Water Tank Bypass Diverter Valve and Plate Assembly Review
- Video: An In-Depth Look at the B and B RV Winterizing Diverter Valve and Plate Assembly
- Q&A: Availability of Soft Start for Dometic FreshJet 5
- Q&A: Recommended Replacement For A Dometic Brisk II Model # B59516
- Q&A: Recommended Tire Pressure for ST Trailer Tires and Load Rating Capacity
- Q&A: Troubleshooting Water Problems at the Check Valve
- Q&A: Replacement Fresh Water Check Valve Options For A 2021 Grand Design Reflection
- Q&A: Where to Install a Valterra Check Valve for RV Fresh Water Systems on a RV Water Heater

