Question:

I have a 2019 Grand Design 344R with a Coleman Mark 3 AC heat pump, and the other is a Coleman Mark 3 AC unit. Want to know which Furrion Chill Cube unit could replace the Coleman Mark 3 heat pump unit?

0

Expert Reply:

Hello Eddie,

Thanks for writing in. To replace your Coleman Mach 3 heat pump on your 2019 Grand Design 344R, I recommend the Furrion Variable Speed Chill Cube RV Air Conditioner with Heat Pump # FR59TQ.

Your Grand Design should have a factory ducted setup, and the # FR59TQ is designed for ducted applications while also fitting the standard 14" x 14" roof opening used by the Coleman units, so the physical installation is usually pretty straightforward.

One important thing to keep in mind is that this needs to be installed as a complete matched system. RV air conditioners completely transitioned from R410A refrigerant systems over to the newer R32 systems beginning in the 2025 model year, so the newer Chill Cube components are not compatible with the older Coleman control systems, thermostats, or air distribution components.

The nice part about the # FR59TQ is that it is already a complete setup with the rooftop unit, controller, thermostat, and air distribution components all designed to work together properly. That makes the transition much simpler since you are replacing the entire heat pump system with components designed around the newer refrigerant platform.

One of the biggest improvements people notice when switching from the older Coleman Mach units to the Chill Cube systems is how much quieter they are. The variable-speed compressor also helps with smoother cooling, lower startup amp draw, and more consistent temperature control compared to the older fixed-speed systems.

Before ordering, I would still recommend verifying that your current setup is ducted by checking whether the air is distributed through multiple ceiling vents throughout the RV instead of blowing directly from the ceiling assembly itself.

Are you replacing the Coleman because it failed, or are you mainly looking to upgrade for quieter operation and better efficiency on your trips?