Is Time Delay Feature on Go Power Transfer TS-30 Switch 34264403 Manual or Automatic
Published 09/19/2018 >
Question:
The manual for the Go Power 30A transfer switch refers to a “time delay bypass switch”. Where is it? The relay control circuit board has no switch on it.
asked by: Henry
Expert Reply:
The instructions for the Go Power Transfer Switch # 34264403 do refer to a "time delay module" that automatically gives generators a brief time to warm up and stabilize their output before it is connected to the load side of the system. This is not a switch you need to operate.
The automatic delay feature allows between 15 and 20 seconds for stabilization. I confirmed this with my contact at Go Power.
This feature can be bypassed but Go Power recommends leaving it active for safety reasons. Bypassing the delay requires modifications (soldering of a jumper wire) and details of this process can be obtained from Go Power.
Product Page this Question was Asked From
Go Power Automatic Transfer Switch - Plastic Case - 30 Amp - 120V
- RV Transfer Switch
- 30 Amp
- 120V
- Shore Power to Inverter
- Go Power
more information >
Featured Help Information
Instructions
Continue Researching
- Search Results: automatic transfer switch
- Search Results: breaker box
- Shop: PowerMax PMDP-30/50 RV AC/DC Distribution Panel - 30A/50A
- Shop: WFCO Auto Detect RV Converter and AC/DC Distribution Panel - 12V - 25 Amp
- Shop: Go Power Automatic Transfer Switch - Plastic Case - 30 Amp - 120V
- Search Results: rv transfer switch
- Shop: Progressive Dynamics 5000 Series AC/DC Distribution Panel - 30 Amp
- Shop: Go Power Automatic Transfer Switch with Quick Connect Cables - Plastic Case - 30 Amp - 120V
- Shop: Progressive Dynamics 5500 Series AC Distribution Panel - 50 Amp
- Shop: Progressive Dynamics 4500 Series Inteli-Power Converter - 75 Amp
- Q&A: Should The Go Power Transfer Switch Time Delay Be Turned Off
- Q&A: What Size Socket is Needed For 2-5/16 Inch Hitch Ball
- Q&A: Trailer Hitch Ball Wrench Size and Torque Rating for 1-1/4 Inch Hitch Ball Shank Size
- Video: Mounting Buttons for Tow-Rax Shelves, Cabinets and Racks Feature Review
- Video: Review of the Optronics LED Transit Tail Light
- Q&A: Will Go Power Automatic Transfer Switch Transfer to Inverter When Shore Power is Lost
- Search Results: 7 pin plug
- Search Results: 6 pin plug
- Q&A: Recommended Power Transfer Switch for Three AC Power Sources
- Search Results: 30 amp rv transfer switch
- Shop: Wheel Liners
- Q&A: Wiring Instructions For The Go Power Automatic Transfer Switch # 34264403
- Q&A: Automatic Transfer Switch For 30 Amp Service
- Search Results: inverter