Question:

I have a LF error. I have extended Jacks 8inch and fully retracted all Jacks. I still have error LF error. I did this 3 times. Its lost its HOME .Can I turn system off press front 10 times and rear 10 times then wait for system to reboot then hit enter.My coach is manually leveled nearly perfectly Thanks

0

Expert Reply:

The LF error on your Lippert Ground Control System # LC358590 indicates an issue at the left front jack or some kind of short or failed power source (like a dead battery). If your battery has a good charge most likely it's a wiring issue.

I recommend simply inspecting the wiring for any frayed or damaged portions that need to be replaced. Also make sure your battery is fully charged and in good condition.

To clear that message Lippert states that you need to extend all of the jacks at least 6 inches. You will then press and hold the retract button until all the jacks begin retracting. Doing this should clear the error code but you will still want to try and track down the reason for the fault if you haven't already.