Question:

I just received DM62VR the 2 yellow wires coming out of back I see 1 is ground and 1 is power. The 5 way flat coming from my boat has blue wire for reverse breaking can the blue wire and 1 yellow wire tie together and then connect both to back up reverse. Thanks

0

Expert Reply:

The electric lockout on the Demco Hydraulic Brake Actuator # DM62VR has 2 yellow wires as they are not positive/negative specific. You will connect one of the yellow wires to your 5-Way # A25W5B blue wire. The other you will connect to ground. I recommend the Heat Shrink Butt Connectors # DW05744-5 and Heat Shrink Ring Terminal # DW05737-1 to keep a weathertight connection on the wiring.