Troubleshooting No Power to MaxxFan RV Roof Vent MA00-04000K
Updated 10/15/2018 | Published 10/12/2018 >
Products Featured in This Question
Question:
I recently went to install my Maxxair 00-04000K 12V Roof Top Fan/Vent and when it came time to power it up.. .nothing. not a beep. Not a light. The power source is good so there must be an issue with the unit. What can I do to fix this? I dont want to remove it if I have to.
asked by: Derek D
Expert Reply:
If you have tested the RV's power and ground wires leading to your MaxxFan Trailer Roof Vent # MA00-04000K and you have a full 12V of power reaching the vent's fan motor then there might be damage to the unit's control circuitry or the motor itself.
If you apply a voltmeter like # PT89ZR to your power source wiring and you are not detecting a full 12 volts then it could be an issue with a depleted battery. This vent's motor draws 5-amps in use.
If you have a spare battery known to be fully charged you can try using this charged battery to test the fan instead of the usual RV power source. This battery can be used to test the entire fan unit as well as to separately test just the motor by connecting the motor leads directly to the battery. If the motor operates when directly powered then the issue is probably in the control board.
Product Page this Question was Asked From
MaxxFan Plus Roof Vent w/ 12V Fan and Thermostat - Manual Lift - 10 Speed - White
- RV Vents and Fans
- Vent
- Roof Vent
- Manual Lift
- 12V Fan
- Reversible Fan
- Plastic
- White
- MAXXAIR
more information >
Featured Help Information
Instructions
Continue Researching
- Shop: Replacement Printed Circuit Board for MaxxAir Powered Lift RV Roof Vents w/ Reversible Fan
- Shop: Replacement Printed Circuit Board for MaxxAir Manual Lift RV Roof Vents
- Shop: Replacement MaxxFan Plus 10-Speed Roof Vent with Smoke Lid
- Shop: Replacement 12-Volt Variable Speed Fan Motor for MaxxAir MaxxFan RV Roof Vents
- Shop: MaxxFan Deluxe Roof Vent w/ 12V Fan, Thermostat, and Remote - Powered Lift - 10 Speed - Smoke
- Shop: Replacement Handheld Remote for MaxxAir Roof Vent Intake/Exhaust Fans - Qty 1
- Shop: Replacement Remote for MaxxAir Roof Vent Exhaust Only Fans - Qty 1
- Q&A: Replacement Circuit Board For A MaxxAir MaxxFan In A 2021 Grand Design Solitude 3540 5th Wheel
- Q&A: Troubleshooting MaxxFan 4700 Series, 4700K
- Q&A: Remote Replacement for MaxxAir 4900K Roof Vent with Fan
- Q&A: Replacement Lift Motor for Maxx Fan
- Q&A: Replacement Circuit Board for MaxxAir Printed Manual Lift RV Roof Vent with 10B21276KZ Board
- Q&A: Remote Control for MaxxFann Deluxe Maual Model 5100K
- Q&A: Troubleshooting A MaxxAir RV Vent That Keeps Trying To Close When Its Already Closed
- Video: Feature Breakdown: Replacement MaxxFan Plus 4-Speed Roof Vent with White Lid
- Video: Review of Maxxair RV Vents and Fans - Enclosed Trailer Parts - Operator Mechanism - MA10-20281K-1AF