bing tracking image
Q & A Icon

What Is The Distance From The Hitch Pin Hole To The Back Of The TorkLift SideKick Tray?  

Updated 09/24/2026 | Published 09/19/2026

Question:

What is the distance between the center if the hitch pin hole and the back edge of the generator tray? I am planing to use it with a maxXpeedingrods 4000Watt inverter dual fuel generator. The size fits the requirements in size but not sure about the exhaust on the back side or the 30 Amp plug on the front side. Can you provide any assistance with the measurments?

0

Expert Reply:

Hello Donald,

Welcome to etrailer, I'm glad you found us!

The distance from the center of the hitch pin hole to the far edge of the TorkLift SideKick # TLA7901 is 27-1/2". The center of the hitch pin hole is 6" from the closest edge of the tray, and the tray itself is 21-1/2" long.

I attached an image showing exactly where those measurements are taken to make it a little easier to compare with your generator.

Based on that 27-1/2" measurement, do you think that will give you the clearance you need for your generator?

expert reply by:
0
Kate F
16x21 TorkLift Lock and Load SideKick Cargo Tray Dimensions
16x21 TorkLift Lock and Load SideKick Cargo Tray Dimensions
(click to enlarge)
Donald D. profile picture

Donald D.

9/22/2026

Thanks. Not sure about how the generator will fit with the two upright arms that hold the generator in the pan. The flame arrester is in the center of the generator an I don’t know if it will discharge against the arm. The other arm needs to allow for the 30 amp plug to attach to the generator and I don’t know if that will fit. Still trying to get more info on the generator.

Kate F. profile picture
Etrailer Expert

Kate F.

9/22/2026

@DonaldD After taking a closer look at your generator, I think I found a better option for you! Take a look at the larger TorkLift Lock and Load Maximum Security Cargo Tray # TLA7752. This one has a much larger 27-3/4" x 24" tray, so you will have a lot more room to position the generator and work around that 30-amp plug. We have actually recommended this larger version before when access to a generator's 30-amp connection was a concern. I like this option a lot better for your setup than trying to squeeze everything into the smaller # TLA7901. You will still get the locking security you are looking for, but with more room to work with. I know it cost a bit more, but it will work.
Robert S. profile picture

Robert S.

9/23/2026

@DonaldD The TorkLift Lock and Load SideKick Cargo Cargo Tray generator tray is a unit that secures Yamaha EF2400iSHC, Yamaha EF2000iS, and Honda Eu2000ia generators while running per their website. I have a Yamaha 2300/1800 and needed to slightly modify the upper horizontal securing cross piece for the generator to fit around the handle. It does not have clearance on this unit for the 30amp plug while running AND it is unlikely to work with units other than those stated. Kate F. is offering solid advice on using a Maximum Security Cargo Tray #TLA7752 as the SideKick is pretty much a custom piece for few models.
Kate F. profile picture
Etrailer Expert

Kate F.

9/24/2026

@RobertS Thanks for the feedback, Donald! You are correct, the SideKick is designed around specific generator models, so even similar-sized generators can have clearance issues. I appreciate you sharing your experience with the Yamaha EF3000iSEB!

Product Page this Question was Asked From


Q & A Icon

Continue Researching

See More Q&A Expert Answers >>