Question:
Can I mount one of these on side wall of enclosed cargo trailer to suck air into trailer and well as one on roof to exhaust?
asked by: Will G
Expert Reply:
Thanks for letting us help Will. While there's nothing that specifically prevents you from installing a powered roof vent like the MaxxFan Mini Plus # MA00-03801 on a vertical wall, these vents are designed primarily for roof installations. Because of that, I'd be concerned about water intrusion over time, especially since the exterior lid and flange are designed with a horizontal installation in mind. The # MA00-03801 also requires a mounting surface at least 1 inch thick. The same requirement would apply if you mounted it vertically. Depending on your trailer's wall construction, you may need to build out the opening to achieve the necessary thickness and add reinforcement to properly support the weight of the fan.
I think a better solution would be to install wall vents like # HMAV2-AVT2, which are specifically designed for enclosed trailer walls and require much less modification. You could then add a powered vent to the roof to create airflow through the trailer.
For the roof, I'd recommend the MaxxFan Plus Roof Vent # MA00-04002K. It's reversible, so you can use it to either exhaust hot air from the trailer or pull fresh air inside. If you don't need the reversible feature, the MaxxFan Mini Plus # MA00-03801 would also be a good roof-mounted option.
For either roof vent, you'll need the Roof Vent Installation Kit # 344270KITW, which includes the butyl tape and self-leveling sealant needed to properly seal the installation. For the wall vents, you'll want a non-sag sealant such as the LaSalle Bristol XTRM Universal Non-Sag Sealant # 344270341437-1.
What are you normally hauling in your enclosed trailer?
Product Page this Question was Asked From
MaxxFan Mini Plus Manual RV Roof Vent w/ 12V Fan - LED Light - White
- RV Vents and Fans
- Vent
- Roof Vent
- 12V Fan
- Plastic
- White
- MAXXAIR
more information >
Continue Researching
- Q&A: Replacement Pin Box For 2025 Keystone Alpine 3820FK
- Q&A: Can The Champion 4,000-Watt Portable Inverter Generator CH79FR Be Used At 6,000 To 10,000 Feet?
- Q&A: Will Air Lift LoadLifter 7500 XL Fit 2026 Ford F-350 Dually With 48 Gallon Fuel Tank
- Q&A: Replacement Bolt For MORryde CRE3000 And X-Factor Crossmember
- Q&A: Availability of Victron DC/DC Battery Charger With Lithium Compatibility and Engine On Detection
- Q&A: Recommended Grease Seals For Dexter 9919860 3,500lb Axles
- Q&A: Recommended Baseplate Kit for a 1974 VW Super Beetle
- Article: Trailer Lighting Requirements
- Article: Can I Put Wallpaper in My RV?
- Article: Best RV Roof Vents
- Article: Brake Controller Installation: Starting from Scratch
- Article: Hydraulic Trailer Brakes: How They Work & What to Buy
- Article: Trailer Wiring Diagrams
- Article: How to Replace a Rubber RV Roof


Mark S.
8/28/2026
Yes it would absolutely work sideways. No issues