Troubleshooting An 88 Error Code On A Furrion RV Fireplace
Updated 11/29/2024 | Published 09/10/2022 >
Question:
I know that means the fan is overheating. I have vacuumed all the vents and it is still showing code 88
asked by: Linda S
0
Expert Reply:
The overheat protection on your Furrion RV Electric Fireplace with Logs # F30SW15ABL is kicking on the so the only way to clear it is to remove it from the power source for 15 mins to fully shut down and to clean out the vents like you stated you already have.
If resetting the unit doesn't solve the issue then the circuit board on it might need to be replaced. This is an item only Furrion would have so you would need to contact them directly.
expert reply by:
Kevin C
0
Featured Help Information
Miscellaneous Media
Continue Researching
- Shop: Solera 12V Electric RV Awning Conversion Kit - 69" Arms - Black
- Shop: Replacement Front Panel Module for 17" and 21" Tall Furrion 2-in-1 Range Ovens - Black
- Shop: TecNiq Dome Surface Mount Light - 4.5" - Round - White LEDs - Without Switch
- Shop: MaxxAir MaxxFan Mini Roof Vent w/ 12V Fan - Manual Lift - 4 Speed - Black
- Shop: Solera Electric RV Awning Conversion Kit w/ Speakers for Flat Awnings - 69" Arms - Black
- Shop: Replacement Front Panel Module for 16" or 22" Tall Furrion 2-in-1 Range Ovens - Black
- Shop: RV Interior Lighting
- Shop: 12V LED RV Dome Light - Single - 5-7/8" Long x 3-3/4" Wide - White
- Q&A: What Does Flashing 88 on Furrion Fireplace Display Mean
- Q&A: Meaning of 88 Error Code on Furrion RV Fireplace

Lisa F.
11/28/2024
How do you remove the cover of the fireplace