If your Power Watchdog EPO surge protector or other smart surge protector is detecting an open neutral or open ground error on your generator, this plug will create a safe connection so you can get power. 1-800-940-8924 to order Hughes Autoformers generator plug adapters part number HU33FR or order online at etrailer.com. Free expert support on all Hughes Autoformers products. Great prices and Fastest Shipping for Hughes Autoformers Ground Neutral Bonded Plug for Generators. Generator Plug Adapters reviews from real customers.
  • All Info
  • Reviews (112)
  • Q & A (0)
  • Videos (2)
  • Photos

Hughes Autoformers Generator Plug Adapters - HU33FR

  • Plug Only
  • Hughes Autoformers
  • Standard Adapter

If your Power Watchdog EPO surge protector or other smart surge protector is detecting an open neutral or open ground error on your generator, this plug will create a safe connection so you can get power.


Features:

  • Plug inserts into an unused outlet on your generator to create a neutral to ground bond
    • Prevents open ground or open neutral error faults on smart surge protectors
    • Not a connector - will occupy one outlet on its own
  • Easy setup - plugs into a 15A AC socket on a generator with floating neutrals
  • UL listed


Specs:

  • Dimensions: 2" long x 1-1/2" diameter
  • 1-Year limited warranty


GNBPLUG Hughes Autoformers Ground Neutral Bonded Plug for Generators

Replaces 45814





Video of Hughes Autoformers Ground Neutral Bonded Plug for Generators

Videos are provided as a guide only. Refer to manufacturer installation instructions and specs for complete information.




Video Transcript for Hands-On with the Hughes Autoformers Ground Neutral Bonded Plug for Generators

What's up everybody. It's AJ with etrailer.com. Today, we're gonna be checking out this Hughes Autoformers generator adapter plug. So what this is gonna do is you're gonna plug this into the floating neutral generator we have here, and we're gonna go to plug in our surge protector. It's gonna detect that it doesn't have a floating neutral anymore. Let check it out.

So what this is gonna do is sometimes when you use one of your smart surge protectors with the lights on there that give you the code. Sometimes you won't allow you to use the power because it says there's an error, which you have a floating neutral or an open ground. It's gonna detect that and think it's not usable power. So what this does is this is gonna plug into the generator here that has the floating neutral and it's gonna create a bond. So then it doesn't have that floating neutral anymore.

Then these codes should say it's all clear and should have power. So let's test it out. We're gonna plug in a surge protector see what codes it's pulling up. You can see right here with the one yellow light means there's an open ground. So it's letting you know, there's an error, thinks there's an error.

We can change that by plugging that adapter in route to unplug the surge protector first. Plug the adapter in. Now replug in the surge protector. And let's see what it says. Looks like we've got two yellow lights.

It's got a good connection, so it's good to go. Overall, I think this adapters is good to have especially if you aren't on soft ground where you can actually ground your generator, these Champions have floated neutral. So you do need to ground them. If you're not on that kind of ground where you can do that, let's say you're tailgating in a parking lot. This will be really good to plug that in, that way at least you have a bonded neutral and you can use your generator. Well, I think that does it. Thanks for hanging out, and hope this helps..

Customer Satisfaction Score:

Ratings & Reviews

4.8

112 reviews
If your Power Watchdog EPO surge protector or other smart surge protector is detecting an open neutral or open ground error on your generator, this plug will create a safe connection so you can get power.

by:

This neutral ground plug did exactly what I expected it to do. Plugged it into my Honda EU3000is generator and my 30amp Hughes Watch dog shore power inlet is green and happy on all three indicators now. Before I had an open ground.



by:

Worked perfectly on my HF 5000 watt gen erator.



by:

This solved the "open ground" problem on my Honda generator. It was as simple as plugging it in and starting the generator.



by:

It did the trick and got rid of my hot neutral reverse light issue from my generator.



by:

I would have preferred a product made in the USA



by:

This product saved me! I had just bought an expensive Honda EU3000is generator and I found that it wasn’t working with my high efficiency furnace. Only the fan would come on without the burner. Come to find out the generator has a floating neutral. I plugged this baby into one of the outlets on the generator, ran a chord out of the other to the furnace and what do you know the bonded signal did the trick! Furnace runs like a champ. Very happy!

Aaron profile picture

Aaron

10/19/2023

This product continues to do the trick after a year. Without it my generator would have made a nice addition to the dump since the only reason I got the generator was to power my furnace in the winter. Thanks again for giving my generator a bonded signal!

Mike L. profile picture
Etrailer Expert

Mike L.

11/9/2023

@Aaron We're happy to hear its working well for you!


by:

It does do what is supposed to do be nice if it had an indicator on it but other than that, it’s excellent buy.



by:

The plug worked as advertised. The only issue I had was at checkout, I chose an option for a Saturday delivery - it didn't arrive until Tuesday. Not the biggest deal, just kind of annoying. Still quick either way!



by:

Well made and it seems to work



by:

Perfect. Does exactly what it is supposed to do. No more ground faults when I power our RV with a generator.



by:

Worked as stated and what I needed for the Hughes EPO Power Watchdog to work with a generator.



by:

Works exactly as described. Easy to use.



by:

Just used it last night for the first time. We have a Wen 3500 inverter generator and with the floating neutral ground I was not able to get my Watchdog surge protector to work last week. I plugged the Hughes Autoformers Ground Neutral Bonded Plug into my generator and everything worked perfectly. I ordered it from Etailers on a Monday and had it in my hand by Thursday. Thank you.



by:

Works as advertised.



by:

It solved my neutral ground issue when using my HOnda generator with my Airstream trailer



by:

works great. should have gotten one years ago and the staff at e trailer are great as well.



by:

It fixed my issue. I have a new home (modular) and the furnace wouldn’t run off generator. With this plugged in I was able to plug my furnace into my portable generator and it worked. Nice to have an emergency backup!



by:

NO! It has not been delivered. I just went out to see and there is no delivery as of yet. Still waiting



by:

The plug arrived in good condition! It was shipped quickly & on time.As usual great service from etrailer, Thanks



by:

Works as designed.



by:

I received the order in a timely manner.



by:

Works as advertised



by:

Thanks works great with Honda generator charging rv batteries



by:

Quick Delivery, Great Quality.



by:

I got what I needed and at a good price. Shipping was fast.


25
112
Show More Reviews

See what our Experts say about this Hughes Autoformers Generator Plug Adapters

  • Watchdog Surge Protector Compatibility With Generator Use
    The Hardwired Power Watchdog Surge Protector with Bluetooth and Emergency Shut Down - 50 Amp Item # HU27FR is compatible with generator use. One thing you will have to note is that some generators have a ‘floating neutral’. This might cause the Power Watchdog EPO surge protectors or any other EMS surge protector to give you an ‘open ground’ or ‘open neutral’ error code and prevent power from going into your RV. If this is the case with your generator you can resolve this by plugging the...
    view full answer...
  • Can Portable Power Watchdog Surge Protector HU32VR Be Used With A Generator?
    Hello Jason, thanks for reaching out. Yes, the Portable Power Watchdog Surge Protector with Bluetooth and WiFi # HU32VR can be used with a generator. One thing you will have to note is that some generators have a ‘floating neutral’. This might cause the Power Watchdog EPO surge protectors or any other EMS surge protector to give you an ‘open ground’ or ‘open neutral’ error code and prevent power from going into your RV. If this is the case with your generator you can resolve this by plugging...
    view full answer...
  • Do I Need a Bonded Plug w/ a 2550 Westinghouse Generator?
    Hey Ron, welcome back. Are you having open neutral or ground errors? This is usually why you would need a Bonded Plug like item # HU33FR. We do not sell Westinghouse generators so I recommend checking your owner's manual, contacting them directly, and/or asking an electrician.
    view full answer...
  • How Are AC And DC Grounds Wired With The Progressive Dynamics PD4045KA Power Center
    The AC and DC sides of the Progressive Dynamics 4000 Series Mini RV Converter w/ Charge Wizard and AC/DC Distribution Panel # PD4045KA would be grounded separately. If plugged into shore power you'll have ground at the pedestal. Generators will typically require an earth ground, whether that's a wire ran to a stake in the ground or a grounding plug like # HU33FR. All AC components ran to the power center will ground to bus bar in the power center and out to the shore or generator out. All...
    view full answer...
  • Can the Power Watchdog Surge Protector with Bluetooth Be Used With a Generator
    Yes, the Power Watchdog Surge Protector with Bluetooth, # HU47FR, for 50 amp and the 30 Amp version, # HU97FR can be used with a generator. However, many generators (portable) have a floating ground/neutral. If you do have a floating neutral generator then you will also need the Hughes Autoformers Ground Neutral Bonded Plug for Generators, # HU33FR to bond the neutral and ground thus preventing an open ground or open neutral error fault to occur.
    view full answer...
  • Hughes Autoformers Portable Power Watchdog Surge Protector use with Generator
    Yes, the Portable Power Watchdog Surge Protector with Bluetooth - 30 Amp, # HU97FR can be used with generators however, many generators (portable) have a floating ground/neutral; so you will want to determine this with yours as you may need an added item. If you do have a floating neutral generator then to use this EPO (emergency power off) you will also need the Hughes Autoformers Ground Neutral Bonded Plug for Generators, # HU33FR you will need this item to bond the neutral and ground.
    view full answer...
  • How Can I Power My Camper From a Generator With the Hard Wired Watchdog Surge Protector?
    As I am not sure of your specific camper there are a couple options to check out. First the Hughes Autoformers Ground Neutral Bonded Plug for Generators # HU33FR is designed to allow you to plug into your generator without causing the Power Watchdog Surge Protector # HU27FR to fault. The plug inserts into an unused outlet on your generator to create a neutral to ground bond. If your generator is an onboard unit that is hardwired to the camper you will want to install the surge protector...
    view full answer...
  • Will Hughes Autoformers Voltage Booster and Watch Dog Work on a House with Generator
    The Hughes Autoformers Voltage Booster with Surge Protection part # HU24FR and Power Watchdog Surge Protector with Bluetooth and Emergency Shut Down part # HU77FR are designed for trailers but so long as you don't try to pull more than 30 amp through them it would not be an issue to use them on a home with generator. The booster is basically a step up transformer, that will boost voltage 2% all the time, and if/when your voltage is low 113V or lower, it will go to a 10% boost. The watchdog...
    view full answer...
  • Is the Hughes Autoformers Voltage Booster with Surge Protection Compatible with a Generator
    No, the Hughes Autoformers Voltage Booster with Surge Protection # HU24FR will not work with your inverter generator. It is designed to be used with a pedestal at an RV park, not a generator. We do not have a voltage booster that will work with a generator. But if you are wanting a surge protector that works with a generator you can use the Power Watchdog Surge Protector # HU27FR. One thing you will want to note is that some generators have a ‘floating neutral’. This could cause the Power...
    view full answer...
  • Surge Protector for Trailer With 15 Amp Service
    Since a 15 amp RV surge protector is not available you can use the # HU97FR you were looking at. Typically you want to match the rating on the surge protector with the service on your trailer, but the 30 amp won't have any issues with your 15 amp. This will require an adapter so you can use the # A10-1530ARDVP. The Honda EU2000i is a floating neutral generator. You will in fact need the Hughes Autoformers Ground Neutral Bonded Plug for Generators # HU33FR. This will create a neutral to...
    view full answer...
  • Troubleshooting An Open Ground Error When Using A Surge Protector With Generators
    Your generators have a floating neutral so that's why you're receiving the open ground error. The solution to this is to plug the Hughes Autoformers Ground Neutral Bonded Plug for Generators # HU33FR into an open 15 amp outlet on the generators. You CAN NOT plug this into any outlets in your Lance 650, only on the generators. These plugs will clear your open ground error and allow your surge protector and generators to properly function.
    view full answer...
  • Can The Hughes Autoformers Ground Neutral Bonded Plug for Generators Be Used On A Power Pedestal
    If the open neutral occurs in the campground pedestal you're only getting one hot line, and there's not a return path for the electricity, so there would be no current flow. If you have an open ground it means that there isn't a ground connected to the receptacle and this could cause damage to your trailer if there's a power surge. The Hughes Autoformers Ground Neutral Bonded Plug for Generators # HU33FR is only designed to plug into a 15A AC socket on a generator with floating neutrals...
    view full answer...
  • How Many Hughes Autoformers Ground Neutral Bonded Plug is Needed For Parallel Generators
    Since your parallel generators are linked together like you said, you will only need to use one of the Hughes Autoformers Ground Neutral Bonded Plug for Generators # HU33FR.
    view full answer...
  • Will Watchdog Surge Protector Give Errors When Using Generator With Jayco Jay Flight?
    Alan, that’s a great question. Yes, the Watchdog Surge Protector # HU72VR works fine with generators, but you may see open neutral or open ground codes if your generator has a “floating neutral.” That’s not the Watchdog malfunctioning - it’s protecting your rig. The fix is the Hughes Ground Neutral Bonded Plug # HU33FR. Just plug that into an unused outlet on the generator, and it bonds the neutral and ground properly. (you may not need this, but figured I'd mention it) Do you plan to...
    view full answer...


Info for this part was:

Employee Andrew K
Installed by:
Andrew K
Employee Michael B
Installed by:
Michael B
Employee Jacob T
Video Edited:
Jacob T
Employee Mary K
Written by:
Mary K
Employee Wilson B
Updated by:
Wilson B
Employee Cody B
Updated by:
Cody B
Employee Amanda M
Edited by:
Amanda M
Employee Jonathan Y
Video by:
Jonathan Y

At etrailer we provide the best information available about the products we sell. We take the quality of our information seriously so that you can get the right part the first time.


Product Experts Available Now!
Call 1-800-940-8924
<