Troubleshooting Solera Slide Out Hall Sig Not Present
Published 02/15/2022 >
Question:
i have 3 slide 5th wheel , big living slide came in fine, big dining room slide came in fine. bed room slide only wants to work on one side going in and out, its like right side of slide hugh up , nothing blocking it. code on 13398-c2 says hall sig not present, need your help on hall sig not present.
asked by: Bertram G
0
Expert Reply:
The hall sig not present according to Lippert means the encoder is not providing a signal which typically is a wiring problem so you'd have to just go over the wiring looking for any obvious shorts to clean up.
expert reply by:
Jameson C
0
Product Page this Question was Asked From
Lippert Replacement Controller for In-Wall Slide-Out - V-Sync II
- RV Slide Out Parts
- Controller Parts
- Controller
- Lippert In-Wall RV Slide-Out Systems
- Lippert
more information >
Featured Help Information
Instructions
Continue Researching
- Q&A: Which 2026 Chevy Equinox Can Be Towed Behind An RV?
- Q&A: Solution for Needing Replacement Controller for Lippert 308958 Schwintek
- Q&A: Availability of Replacement INwall My RV Control Panel 308958
- Q&A: Replacement Controller For Lippert 366071 Dual Gear Motor Sync Control
- Q&A: Which Dometic Fridge Will Fit Same Space as Norcold N8XFL
- Q&A: Troubleshooting A Slide Out Box That Stops Before Fully Sealing Closed
- Q&A: Replacement For 1510000236 Slide-Out Controller
- Article: Frequently Asked Questions About Transmission Coolers
- Article: Towing a Trailer? Let's Talk About Brake Controllers
- Article: Troubleshooting Brake Controller Installations
- Article: RV Sway Control, Stabilization, and Suspension Enhancement
- Article: What are the Common Types of Propane Fittings Used on RVs?
- Article: How to Accurately Measure Trailer Leaf Springs
- Article: How to Tell the Weight Rating of a Trailer Axle