Updated 09/08/2024 | Published 02/23/2020

Question:

Hello, How much current or power if thats easier does the ground control 3.0 system require both as a average and maximum? Also how much does each leg use when operating? Thanks for any help you can provide. Regards,

0

Expert Reply:

The power circuit for each leg of the Lippert Ground Control leveling system # LC358590 is protected by a 35 amp fuse. That means that at most the entire unit could draw up to 140 amps at a time. Realistically it would probably be considerably less but that really depends on the weight of the trailer.

expert reply by:
0
Jameson C
Jim B. profile picture

Jim B.

9/6/2024

The installation manual recommends a 50 amp breaker from the battery to the system. That would mean the system should pull something less than 50 amps.

Jameson C. profile picture
Etrailer Expert

Jameson C.

9/8/2024

@JimB good to know!