bing tracking image
Q & A Icon

What is Max Gauge Wire Wago 221 Connectors of Progressive Dynamics 4500 60 Amp Converter Can Use  

Updated 03/16/2026 | Published 02/23/2026

Question:

Since this model has switched to Wago connectors for the DC circuits, what is the largest DC wire gauge for the two sizes of Wago connectors? Thanks!!

0

Expert Reply:

Hey Wade, since the Progressive Dynamics Panel part # PD4560K18LS8 uses Wago 221 connectors the max gauge wire it can be used with is 10 gauge. What gauge wire were you planning on using?

expert reply by:
0
Jameson C
Wago
Wago
(click to enlarge)
Wade profile picture

Wade

3/13/2026

There are 4 larger Wagos that accept 8AWG. I should have been more specific. Dare I ask their max amp rating? I'm guessing it's greater than 30amp, but it would be nice to know. My instructions don't even show the new Wagos as present in this panel. Thanks.

Jameson C. profile picture
Etrailer Expert

Jameson C.

3/16/2026

@Wade I checked and the WAGO 221-612 is the one that can accept up to 8 gauge wire and it is rated for 30 amp. That does seem pretty low for something handle 8 gauge wire.