Do The Furrion Chill Cube AC Units Have A Soft Start Installed?  

Updated 11/20/2026 | Published 02/25/2025

Question:

Does this have a softstart installed? If no, what would you recommend to install a soft start on this unit

0

Expert Reply:

Hello Emon, thanks for reaching out.

No, the Furrion Chill Cube AC Units like part # LC54DX do not have a soft start installed. These units start up in different stages, so you do not get big amperage spikes during startup like you do with other units. For this reason a soft start really would not be needed.

Sadly, we do not yet have any concrete numbers for the startup amperage. We have installed a few of these units, but it isn't warm enough here in Missouri to actually get the compressor running at full power. The running amps are between 10 and 18 roughly. Once things warm up outside we will be able to test the unit at full power and get accurate numbers. For now the consensus is a soft start is not needed.

expert reply by:
0
Jesse M
Furrion Chill Cube
Furrion Chill Cube
(click to enlarge)
Jesse M. profile picture
Etrailer Expert

Jesse M.

10/30/2025

Hey Emon, how has the Furrion Chill Cube AC been performing without a soft start added? It’d be great to know if the staged startup kept things smooth once the weather warmed up. Your update could help others thinking about the same setup.

Rich S. profile picture

Rich S.

11/19/2026

@JesseM Hi, I have a 2026 Brinkley Z3100 with two 18,000 BTU Furrion Chill Cubes. One is non-ducted and one is ducted with heat pump. I'm not sure of the model numbers. I have no problem starting/running both of them on a 30 amp circuit. However, when either unit starts up it is loud and shakes the RV. If the Chill Cube has a inverter compressor and staged startup, it doesn't seem like it should be doing this. I haven't used an amp meter to verify, but from what I've read all Furrion Chill Cubes have inverter compressors and staged startup. If that is accurate, will a soft start do any good. Will it reduce startup noise and shaking? I was ready to buy the soft start until I read about the inverter compressor and staged startup. Thanks, Rich S.
Jesse M. profile picture
Etrailer Expert

Jesse M.

11/20/2026

@RichS Hey Rich! You're correct that the Furrion Chill Cube units use inverter-driven compressors with a gradual startup, so aftermarket soft starts are not recommended for these units. It really wouldn't do any good. I've actually tested and used several of these Chill Cube units here at our shop, and none of them have been particularly loud or caused noticeable shaking during startup. Based on my experience, what you're describing definitely isn't normal, and I'd suspect something isn't quite right with the installation or the units themselves. I'd start by checking the rooftop mounting bolts, roof gaskets, and interior air distribution boxes for anything loose or improperly secured. Does the shaking only happen for a few seconds when the compressors first start, or does it continue while the units are running?
Rich S. profile picture

Rich S.

11/20/2026

@JesseM Thanks for the info. Yes its at startup and just briefly. I've read other people have had the same issue. Some people have had success tightening the compressor mounting bolts. One person said the compressor is mounted on springs and that allows the compressor to move sideways when it kicks on and contact the mounting bolts. They recommended putting a piece of rubber hose over the bolt and then properly tightening the bolts.
See All (6) Replies to Jesse M. ∨