Question:
We have a electric gas combo the electric will not turn on unless the gas switch is turned on. Why would that be I have a combo in my other unit with the same switch and you can run the gas and electric independently from each other.
asked by: Dave S
Expert Reply:
I feel confident that the wiring behind the Atwood # AT91230 wall panel is not correct. I would disconnect all 120 volt electric and 12-volt DC then take that panel off the wall and compare it to the wiring diagram I have attached. This should be relatively easy as the plugs push or pull on/off of the spades on the back. I have also attached a video review of that switch.
Product Page this Question was Asked From
Double-Panel On/Off Switch for Dometic Gas / Electric Combination Water Heaters - White
- Accessories and Parts
- RV Water Heater
- Switches
- White
- Dometic
more information >
Featured Help Information
Miscellaneous Media
Continue Researching
- Q&A: Replacement for Atwood G6A-7 on 2001 Coachman Catalina
- Q&A: Recommended Replacement for Atwood G6A-7 Water Heater
- Q&A: My Fogatti InstaShower 8 Plus RV Tankless Water Heater Won't Fire Up, Need Troubleshooting
- Q&A: Replacement SA1250FO-02 Battery for Hopkins Trailer Breakaway System
- Q&A: What Would Cause Keystone Carbon 358 Suspension to Sag
- Q&A: Recommended Lift Kit for 8,000 lbs Axles
- Q&A: Replacement Water Heater for Atwood G6A-3
- Article: Performance Chips and Modules
- Article: Trailer Wiring Diagrams
- Article: Converting Your RV Water Heater to Tankless
- Article: Sidewinder with Rotating Turret for Short Bed Pickups