bing tracking image
Q & A Icon

Replacing a Magnum MS2812 With a Victron MultiPlus II or Quattro II Inverter Charger  

Updated 08/25/2026 | Published 08/07/2026

Question:

i am needing to replace a magnum ms2812 inverter charger, will this unit work to replace it, 2 30 amp ac inputs, 2 30 amp ac outputs thanks

0

Expert Reply:

Hey Steve, happy to help!

The Victron MultiPlus II # VN43VR you're looking at can replace many of the functions of your Magnum MS2812, but there's an important difference with the AC connections.

The # VN43VR has one AC input and two AC outputs. Since you mentioned your current setup uses two 30 amp AC inputs and two AC outputs, the MultiPlus II would not duplicate that configuration.

If you need to retain two independent AC inputs and two AC outputs, I'd recommend the Victron Quattro II Inverter Charger # VN42VR instead. The Quattro II has two AC inputs specifically so it can accept separate AC sources, such as shore power and a generator, and automatically switch between them. It also provides two AC outputs.

The # VN42VR is a 12V system with 2,400 watts of continuous inverter output, 5,500 watts peak output, a 120 amp battery charger, and a 50 amp transfer switch.

Neither Victron would be a direct wire for wire replacement for the Magnum, so some changes to the existing wiring and controls will be necessary. But based on the two input and two output configuration you described, # VN42VR would be the Victron option I'd recommend over # VN43VR.

Are your two existing 30 amp inputs coming from shore power and a generator, or are they both being supplied from the same AC source?

expert reply by:
0
James D
Steve P. profile picture

Steve P.

8/20/2026

they are both being supplied from same 50 amp rv service, seperated in breaker panel with 30 amp breakers of each leg of 50 amp power. do you know of a way to take the vn42vr and keep both legs hot from battery power? from what i have read when no ac power it will only supply (1) leg of ac power and turn off the 2nd to keep from draining battery

Lazer S. profile picture
Etrailer Expert

Lazer S.

8/25/2026

@SteveP On the Victron Quattro-II # VN42VR, AC Out 1 remains powered in inverter/battery mode and supplies 120V to both L1 and L2. AC Out 2 shuts off when shore/generator power is lost. So, if you want both sides of your RV breaker panel powered from the batteries, those loads need to be connected to AC Out 1. Just note that the inverter does not provide true 240V while running on battery.