Troubleshooting A MaxxAir MaxxFan Deluxe With A Non-Working Fan
Updated 04/18/2023 | Published 04/16/2023 >
Products Featured in This Question
Question:
Maxxair Deluxe 7500... Everything worked when shut off at end of last summer no use during winter Vent opens and closes with remote and built-in controller... Fan will not come on with either remote or built-in controls Removed blade screen and blades move freely by hand... How would I determine whether it is switch or motor?
asked by: Dennis P
Expert Reply:
Before you start taking anything apart you'll want to test the power and ground connections to ensure that the vent # MA00-7500K has what it needs to properly operate. If your vent has a bad ground it can cause it to act strangely and if it's not receiving a full 12 volts then it could complete some functions (opening and closing) while others won't work.
To test the motor # MA10-20968 you would need to remove it and cut off the connector (with enough wire to splice it back on) to put power and ground to it with a battery. If the motor starts up then we know it isn't the cause and that the circuit board or the keypad needs to be replaced.
Since you've tried the remote and still won't work the keypad # MA10-21304K most likely isn't the cause, which would leave just the circuit board # MA10A21275K as the cause of the issue.
Product Page this Question was Asked From
MaxxFan Deluxe Roof Vent w/ 12V Fan, Thermostat, and Remote - Powered Lift - 10 Speed - Smoke
- RV Vents and Fans
- Vent
- Roof Vent
- Powered Lift
- 12V Fan
- Reversible Fan
- Plastic
- Tinted
- MAXXAIR
more information >
Featured Help Information
Instructions
Continue Researching
- Shop: Replacement Printed Circuit Board for MaxxAir Powered Lift RV Roof Vents w/ Reversible Fan
- Search Results: maxxfan plus
- Shop: Replacement 12-Volt Variable Speed Fan Motor for MaxxAir MaxxFan RV Roof Vents
- Video: Review of Maxxair - RV Vents and Fans,Enclosed Trailer Parts - MA10-20968
- Video: Review of Maxxair RV Vents and Fans - Enclosed Trailer Parts - MA10A21275K
- Q&A: Troubleshooting MaxxFan Deluxe Roof Vent Remote Control Fan Issue
- Q&A: Amp Draw of Replacement 12V Variable Speed Fan Motor # MA10-20968
- Q&A: Replacement Motor for a MaxxAir MaxxFan 5301K
- Q&A: Replacement For MaxxFan 4500K That no Longer Starts
- Q&A: Replacement Parts For a MaxxAir MaxxFan Deluxe 8951K
- Q&A: Vent Doesn’t Open After Replacing Circuit Board # MA10A04751KS
- Q&A: Troubleshooting Fan Blades Not Turning on MaxxFan Deluxe Roof Vent
- Video: Review of Maxxair RV Vents and Fans - MA39FR
- Shop: Replacement Printed Circuit Board and Switch for MaxxFan Roof Vents
- Shop: Replacement Keypad for MaxxFan Deluxe Roof Vent
- Shop: Replacement Keypad for MaxxFan Deluxe Roof Vent
- Shop: Replacement Printed Circuit Board for MaxxAir Powered Lift RV Roof Vents w/ Exhaust Only Fan