Cannot retract Jacks, giving a lr jack error code
asked by: Eve A
Expert Reply:
The LR Jack error code is identifying that there is an electrical issue with the left rear jack of your Lippert Ground Control 3.0 Electric 5th Wheel RV Leveling System # LC358590. You will need to check the fuse on the main controller for damage as well as the connections and wiring for the jack. Once you have all the wiring checked and if the jack starts to work again you will need to rehome all the jacks. This is done by extending all the jacks at least 6" and using the retract all button for the computer to rehome all the jacks.
If you cannot find any wiring issues you may have a bad jack, you need to manually retract the jack to get it to a service center or home. You can retract your jack with a 3/8" ratchet and extension on the top access point. If you cannot access the top port there is a access port on the bottom but you will also need a 5/16" socket.
Product Page this Question was Asked From
Lippert Ground Control 3.0 Electric 5th Wheel RV Leveling System w Touchpad - 4-Point Set
- Camper Jacks
- 5th Wheel Camper
- Stabilizer Jacks
- Steel
- 10001 lbs or More
- Electric Jack
- 36 Inch Lift
- Bolt-On
- 4 Jacks
- Lippert
more information >
Featured Help Information
Instructions
Miscellaneous Media
Continue Researching
- Search Results: wfl1300xd
- Shop: Trailer Hitch
- Search Results: hitch receiver
- Search Results: 7 pin
- Search Results: hitch
- Search Results: trailer wiring
- Search Results: rotary latch
- Search Results: lasalle bristol rv waste valves
- Shop: Replacement Main Board Assembly for WFCO Auto-Detect RV Power Centers - 55 Amp
- Shop: LaSalle Bristol Cable-Actuated RV Waste Valve - Black Water Tank - Spigot to Spigot - 96" Cable
- Shop: Replacement 22-1/2" Left Rear Leg for Lippert Ground Control 3.0 Electric Leveling System
- Shop: LaSalle Bristol Cable-Actuated RV Waste Valve for Black Water Tank - Spigot to Hub - 96" Cable
- Shop: Dometic CT Thermostat and Control Board - Single Zone - Black
- Shop: Victron MultiPlus-II Inverter Charger with 2 AC Outputs - 2,400 Watts - 50 Amps - 12V - UL Listed
- Shop: Lippert Replacement Hydac Cartridge Valve for RV Slide-Out Hydraulic Pump
- Shop: Trailer Wiring
- Q&A: Can You Purchase the Shorter 22.5 Inch Rear Legs with the Lippert Ground Control System 3.0?
- Q&A: Replacement Right Rear Lippert Ground Control Jack Leg that is 24-1/2 inches Tall
- Q&A: Should The Trailer Brake Circuit Have Continuity Between the Blue Power Wire and Ground?
- Q&A: How To Measure For 5th Wheel Skirting
- Q&A: How to Replace a Hydac Cartridge Valve on a RV Slide-Out Hydraulic Pump
- Q&A: Troubleshooting LF Error On Lippert Ground Control 3.0 Auto Leveling System
- Q&A: Troubleshooting LF Error With Lippert Power Jacks
- Video: Review of Lippert Replacement Hall Effect Sensor Wire Harness Ground Control 3.0 - LC65ED