Why Would RV Water Pump Cycle Off and On When Not in Use
Updated 09/23/2020 | Published 09/22/2020 >
Question:
Hi, I have had the pump installed for six months and was working wonderfully. Now it’s cycles on intermittently about every 10 or 15 seconds. If I turn it off and check the system after 10 minutes the water pressure is gone. I know that sounds like a leak in the plumbing but I cannot find any evidence of a leak. Could it have something to do with the check valve in the pump?
asked by: Scott
Expert Reply:
It's possible a valve isn't sealing well but normally this problem is a slow leak somewhere. The Water Pump # P25201 does have a one-way check valve that was designed to prevent backflow contamination of fresh water. If somehow this went bad it could cause the problem you described so if you go over everything and can't find a leak the pump is at fault.
Product Page this Question was Asked From
HydroMax RV Fresh Water Pump - 12 Volt - 3 Gallons Per Minute - 55 psi
- RV Water Pump
- Diaphragm Pump
- 3 gpm
- 55 psi
- 10 Amps
- 12V
- HydroMax
more information >
Continue Researching
- Q&A: Replacement Fresh Water Pump Options For A ShurFlo 2088-442-144 Pump
- Q&A: Suspension Upgrades for 2017 Grey Wolf 22RR
- Q&A: Recommended Replacement for Atwood GC6AA-10E Water Heater
- Q&A: Recommended Replacement for Shurflo 4008-101-A65
- Q&A: Recommended Replacement for ShurFlo Water Pump 2088-404-144, the HydroMax P25201
- Q&A: Recommended Water Pump to Replace a Shurflo 2088-422-144
- Q&A: Recommended Replacement for a Shurflo 4900-0201 Water Pump
- Article: How to Install E-Track in 3 Easy Steps
- Article: What are the Common Types of Propane Fittings Used on RVs?
- Article: How Much Solar Power Do I Need For My RV?
- Article: How Does an RV Water Pump Work?
- Article: Trailer Maintenance Schedule
- Article: How to Measure for Trailer Hitch Drop
- Article: Which RV Propane Tank Size Do I Need?