Wiring Advent Air RV Air Conditioner w/ Air Distribution Box and Wall Thermostat  

Updated 12/09/2024 | Published 03/19/2022

Question:

How many wires do I need to the thermostat and does it need its own 12 V sauce

0

Expert Reply:

The Advent Air RV Air Conditioner w/ Air Distribution Box and Wall Thermostat, # ADV44FR has four wires to thermostat. Purple connects to B position, blue to A, with red being the needed 12VDC and gray to COM.

expert reply by:
0
Michael R
Thermostat
Thermostat
(click to enlarge)
Eddie T. profile picture

Eddie T.

12/8/2024

Good information on the wording for the wiring on my avent thermostat . Can you tell me the the correct dip switch position . Thank you

Kate F. profile picture
Etrailer Expert

Kate F.

12/9/2024

@EddieT Hello Eddie. It all depends on what you would like on. Here are the different settings for the DIP switch on the back of the unit: - DIP Switch 1: OFF (Heat Strip function disabled) - DIP Switch 2: OFF (Heat Pump function disabled) - DIP Switch 3: ON (Furnace function enabled) Whenever you change the DIP switch it is required to do a factory reset. You can do so by: -Make sure the thermostat is in "Off" mode. You can turn it off by holding the on/off button for 3 seconds. - Start the reset process by holding down the "Mode" and "Fan" buttons at the same time - While holding those 2 buttons down, press the "On/Off" button once, then let go of all the buttons. The screen will flash to show that the reset was complete. After doing this you will need to set up your preferences again, as everything will go back to the original default settings.

Video/Article/FAQ this Question was Asked From

Article or Video
Q & A Icon

Continue Researching

See More Q&A Expert Answers >>