How to Determine the AC BTU Rating Needed to Cool an Enclosed Trailer
Updated 07/21/2024 | Published 01/18/2020 >
Question:
I have a 28ft trailer that is 8.5ft wide with 7ft ceiling. Should I go with one or two roof top units? I am in SC where it get really hot with high humidity.
asked by: Sheldon B
0
Expert Reply:
Based on the square footage of your 28 foot utility trailer the minimum BTU rating you'd need from an AC unit would be 4,760. So the Advent 15k BTU unit part # ACM150C would easily handle cooling your trailer. There'd be no need to add a second unit.
To determine how much BTU is needed for a trailer you take the square footage and multiply it by 20 btu and that's the minimum needed.
expert reply by:
Jameson C
0
Continue Researching
- Search Results: microwave
- Search Results: rv microwaves
- Search Results: fishing rod
- Q&A: Recommended Air Conditioner for 28' Car Trailer
- Shop: etrailer Trailer Hitch Receiver - Custom Fit - Matte Black Finish - Class III - 2"
- Shop: Trailer Hitch
- Q&A: Can 2,200 Watt Honda Generator Power Avent AC # ACM135CH
- Q&A: What is the Correct Size AC Unit for a 30 Foot Long Trailer
- Q&A: Amperage and Wattage Draw of Advent Air RV Air Conditioner # ACM135CH
- Q&A: Can you Run Dual Air Condtioning Units on a 30 Amp 4000 Watt Inverter
- Q&A: Heat Strip For Advent Air Conditioners
- Search Results: rv water heater
- Video: All About the Dometic RV Water Heater
- Search Results: duo~therm
- Shop: Inno Rod Box Rooftop Fishing Rod Carrier - Locking - 8 Fishing Poles
- Q&A: Recommended Microwave To Replace An RV Samsung Microwave
- Shop: Furrion Chill HE Replacement RV Air Conditioner Unit for Furrion Setup - 13,500 Btu - Black
- Shop: Air Distribution Box w/ Built-In Thermostat for Advent Air RV Air Conditioners - White - R32
- Search Results: rv air conditioners
- Shop: GE Profile RV Water Heater - Gas/Electric - 120V - 10,000 Btu - 6 Gallon Tank
- Shop: GE Profile RV Water Heater - Gas/Electric - 120V - 10,000 Btu - 10 Gallon Tank
- Shop: High Pointe Built-In RV Convection Microwave - 1,000 Watts - 1.1 Cu Ft - Black
- Article: What Size Generator Do You Need to Run an RV Air Conditioner?
- Search Results: acmsckit
Kevinb
7/20/2024
It seems from the 20 BTU/square foot formula that most camping trailer's A/Cs are way oversized. Am I missing something? We have a 22ft Bambi Sport Airstream and the A/C is 13,000 BTU, which ramps our 3,000 watt Honda Generator up to over 2,000 RPM. It gets very cool very fast, but the generator gets noisy and it would eat up the tank of gas in less than 4 hours--so I would say it's very oversized for the North East where we use it. Perhaps 13,000 BTU would be needed in Arizona. Trying to run the factory A/C from solar is a non-starter. In the future I hope manufacturers will "right size" the A/Cs to reduce their energy appetites.