Features: Replacement Pollak Defender DC contactor protects your electrical toughness from fire trucks to earthmovers So tough it can handle environments with extreme temperatures, moisture and high vibration Designed to carry currents as low as 350 milliamp and as high as 200 amps Coil Transient Volt Suppression (TVS) - the Defender protects sensitive components in your system Built-in TVS and wide ranging current capability - defends with durability, capability and tenacity-which makes it perfect for off-road and emergency equipment Specs: Coil terminals: Deutch 2-pin connector DT06-25 Contact studs: 5/16-24 studs Mounting bracket: closed holes mounting bracket O-ring material: O-rings (7) - Buna N Standard operating temperature range: -40 to 185 degrees F (-40 to 85 degrees C) Model: 12V cont.
Replaces the sealed DES-2012 contactor for your 12V ComeUp winch. Waterproof construction is fully sealed to protect sensitive electronics.Features: Replaces the sealed DES-2012 contactor for your 12-volt ComeUp winch Waterproof construction is fully sealed to protect sensitive electronics Amp rating: 250 amps
Replaces the contactor on your Bulldog Winch trailer winch. Fits Bulldog Winch 15,000-lb (10063 and 10064), 16,500-lb (10057 and 10058), and 18,500-lb (10059 and 10060) heavy-duty winches.Features: Replaces the contactor on your Bulldog Winch trailer winch Fits Bulldog Winch 15,000-lb (10063 and 10064), 16,500-lb (10057 and 10058), and 18,500-lb (10059 and 10060) heavy-duty winches.
Features: Replacement Pollak reversing polarity DC contactor is great for Truckwinch, tarp systems, boatlifts, RV slide-outs, and RV leveling systems Simple solution for reversing polarity of permanent magnet DC motors Integrating 2 DC contactors into a single unit to streamline the assembly Less assembly time, less potential for problems and more reliable performance The RP can also be customized to specific motors and load requirements Relay is dust and splash resistant Specs: Coil terminals: (2) low-current terminals (1/4" spade), (4) 5/16-24 Studs - high-current terminals, (2) for motor and (2) for battery Standard operating temperature range: -40 to 122 degrees F (-40 to 50 degrees C) Model: 12V high performance Max sustained duty cycle: 16 percent Max on time: 2 minutes Pull in voltage: 8 volts Hold voltage: 2.5 volts Coil resist ohms: 5.6 Resistive load carry/interrupt capability: 75 for 2 minutes (140 for 30 seconds), 250 amps Inductive load carry/interrupt capability: 75 for 2 minutes (140 for 30 seconds), 250 amps Peak inductive inrush capability: 500 amps Electrical cycle life: 5,000 Contact material: copper with silver alloy plating
Features: Replacement Pollak continuous-duty PowerSeal AH contactor with a sealed designed for electric vehicles Also great for electric pallet jacks, fork trucks, floor scrubbers, utility vehicles, and golf carts Environmentally sealed for higher performance - it passes IEC 60529, IP66 and IP67 12V: Can carry 300 amps for 60 seconds or 400 amps for 30 seconds Can interrupt current - 400 amps for 100 cycles over the expected product electrical life Certified for RoHS, REACH and Conflict Mineral Free Specs: Coil terminals: (2) 10-32 studs (non-grounded) Contact studs: 5/16-24 studs Mounting bracket: flat or L flat Standard operating temperature range: -40 to 149 degrees F (-40 to 65 degrees C) Model: 12V cont.
Features: Replacement Pollak continuous-duty PowerSeal contactor for electric vehicles Also great for electric pallet jacks, fork trucks, floor scrubbers, utility vehicles, and golf carts Environmentally sealed for higher performance - it passes IEC 60529, IP66 and IP67 12V: Can carry 300 amps for 60 seconds or 400 amps for 30 seconds Can interrupt current - 400 amps for 100 cycles over the expected product electrical life Certified for RoHS, REACH and Conflict Mineral Free Specs: Coil terminals: (2) 10-32 studs (non-grounded) Contact studs: 5/16-24 studs Mounting bracket: flat or L flat Standard operating temperature range: -40 to 149 degrees F (-40 to 65 degrees C) Model: 12V cont.
Features: Replacement Pollak full silver continuous duty DC contactor works for golf carts, pallets, jacks, forklifts Sealed SPST DC contactor is high performing Patented product design IP66 and IP67 rated Hydraulic power pack Specs: Coil terminals: (2) 10-32 studs (non-grounded) Contact studs: 5/16-24 studs Mounting bracket: flat Standard operating temperature range: -40 to 149 degrees F (-40 to 65 degrees C) Model: 12V cont.
Replaces the contactor in your Superwinch Tiger Shark off-road winch.Features: Replacement contactor for Superwinch Tiger Shark off-road winch Works with SW1511200, SW1511201, SW1517200, SW1595200, and SW1595201 winches
Features: Replacement Pollak standard plastic contactor is great for lawn and garden, golf carts, floor sweepers, and electric motors Durable, high-temperature-resistant plastic housing is suitable for a variety of environmental conditions High temperature coil assembly and brass carrier for the moving contacts stand up under punishing cranking duty Provides an extra margin of weld protection under the worst conditions Specs: Coil terminals: (2) 10-32 studs (non-grounded) Contact studs: 5/16-24 studs Mounting bracket: straight Standard operating temperature range: -40 to 140 degrees F (-40 to 60 degrees C) Model: 12V Max sustained duty cycle: 15 percent Max on time: intermittentt Pull In voltage: 8.5 volts Hold voltage: 4 volts Coil resist ohms: 3.5 Resistive load carry/interrupt capability: 200/200 amps Inductive load carry/interrupt capability: 200/200 amps Electrical cycle life: 10,000 Contact material: copper
Features: Replacement Pollak Bear DC contactor Strong construction and the ability to "bear" a high current-carrying capability Big, but efficient - provides a solution to high-current switching applications Transportation, large machinery, and portable vehicles that carry multi-battery systems are excellent candidates to take advantage of the Bear's strengths Specs: Coil terminals: (2) 10-32 studs Contact studs: 5/16-24 studs Mounting bracket: flat Standard operating temperature range: -40 to 185 degrees F (-40 to 85 degrees C) Model: 12V cont.
Features: Replacement Pollak Defender DC contactor protects your electrical toughness from fire trucks to earthmovers So tough it can handle environments with extreme temperatures, moisture and high vibration Designed to carry currents as low as 350 milliamp and as high as 200 amps Coil Transient Volt Suppression (TVS) - the Defender protects sensitive components in your system Built-in TVS and wide ranging current capability - defends with durability, capability and tenacity-which makes it perfect for off-road and emergency equipment Specs: Coil terminals: Deutch 2-pin connector DT06-25 Contact studs: 5/16-24 studs Mounting bracket: closed holes mounting bracket O-ring material: O-rings (7) - Buna N Standard operating temperature range: -40 to 185 degrees F (-40 to 85 degrees C) Model: 24V cont.
Features: Replacement Pollak intermittent-duty PowerSeal contactor with sealed design is great for hydraulic power pack switching The muscle that drives hydraulic power packs on tractors, pallet jacks, tailgate lifts, snowplows, and other applications Specs: Coil terminals: (2) 10-32 studs (non-grounded) Contact studs: 5/16-24 studs Standard operating temperature range: -40 to 179.6 degrees F (-40 to 82 degrees C) Model: 12V intermittent Bracket: L flat Max sustained duty cycle: 25 percent Max on time: 6 minutes Pull in voltage: 6 volts Hold voltage: 3.5 volts Coil resist ohms: 5.4 Resistive load carry/interrupt capability: 150/250 amps Inductive load carry/interrupt capability: 150/250 amps Peak inductive inrush capability: 800 amps Electrical cycle life: 100,000 Contact material: copper
Features: Replacement Pollak full silver continuous duty DC contactor works for golf carts, pallets, jacks, forklifts Sealed SPST DC contactor is high performing Patented product design IP66 and IP67 rated Hydraulic power pack Specs: Coil terminals: (2) 10-32 studs (non-grounded) Contact studs: 5/16-24 studs Mounting bracket: flat Standard operating temperature range: -40 to 149 degrees F (-40 to 65 degrees C) Model: 24V cont.
Features: Replacement Pollak standard plastic contactor is great for lawn and garden, golf carts, floor sweepers, and electric motors Durable, high-temperature-resistant plastic housing is suitable for a variety of environmental conditions High temperature coil assembly and brass carrier for the moving contacts stand up under punishing cranking duty Provides an extra margin of weld protection under the worst conditions Specs: Coil terminals: (2) 10-32 studs (non-grounded) Contact studs: 5/16-24 studs Mounting bracket: flat Standard operating temperature range: -40 to 140 degrees F (-40 to 60 degrees C) Model: 24V cont.