Question:
One of the stabilizer switches would only retract. We bought a new switch and installed it. Now none of them will work. When we press in any of the switches the red light blinks in the fuse box as if blown. We check and it was good. Replaced it with a new fuse but still nothing works. Suggestions to try! We have checked the motor and they still work when current is applied to it. Put the old switch back in and still none work.
asked by: Linda R
Expert Reply:
When troubleshooting the stabilizer jacks like the Lippert High-Speed Power Stabilizer Jack # LC298707 the manufacturer provides a few options for what to check when the system is not responding to the switches.
Low Voltage:
- Test battery voltage under load. Charge or replace.
- Use Manual Override
Damaged or disconnected wiring:
- Check wiring. Repair or replace.
- Use Manual Override.