Replacement Fireplace Recommendation For A Greystone 324-000066 Fireplace That Is Turning Off & On
Published 02/08/2023 >
Question:
I have the Greystone fireplace. It was on then it started going off coming back on, going off coming back on while the digital numbers were also doing the same. I checked the breaker for it, it was good. I unplugged it, nothing changed. It wont come on. Do you have any suggestion? Thank you
asked by: Judy
Expert Reply:
According to the owner's manual for your Greystone 324-000066 fireplace, this would indicate that the overheat protection in the appliance has been triggered or the house circuit breaker was tripped
To attempt to remedy the issue, Greystone recommends that you turn off and unplug the appliance, allow the insert to cool down for at least 10 minutes and then plug the appliance back in. Also, reset the breaker if it has been tripped.
If the issue is still occurring, then I recommend replacing the entire unit with the:
-Furrion Electric RV Fireplace with Logs - 34" Wide # FF34SW15ABL.
Attached are a couple of product videos for you to check out as well.