View Cart

Popular Brands By Category

Towing

Sports & Recreation

Trailer

Vehicle

RV & Camper

What our customers are saying:

I received this order yesterday. Thanks for the outstanding service. I appreciate it! Thanks, Alex

Alex

Blowing Rock, NC


Maxxair





Maxxair Reviews and Installation Videos


Expert Answers about Maxxair

  • Amp Draw of MaxxFan Deluxe RV Fan
  • While running the MaxxAir MaxxFan Deluxe # MA00-06401K requires about 4-1/2 amps. For startup it will pull around 9 amps.
    view full answer...

  • Troubleshooting MaxxAir MaxxFan 12V Fan-Powered Trailer Roof Vent That Beeps
  • My contact at MaxxAir advised that there are three potential causes for the beep and no fan motion you're experiencing with your MaxxFan Trailer Roof Vent # MA00-04000K. One potential cause is that the unit was wired with incorrect polarity. Make sure the white wire is grounded and the black wire is connected to your 12V power source (of at least 5-amps). Another possible reason for the malfunction is low incoming voltage. Use a voltmeter like # BTMT15 to make sure your battery is delivering...
    view full answer...

  • Availability of AC Shroud to Fit a Coleman Mach AC Unit
  • Yes, the MaxxAir shroud part # MA00-325001 is a fit for the Coleman Mach, Mach 1, Mach 3 and Mach 15 models and mounts like the original and includes mounting hardware and instructions. I attached a review video for this for you to check out as well.
    view full answer...

  • Is the MaxxFan Deluxe Roof Vent # MA00-06401K Exhaust Only
  • The MaxxFan Deluxe Roof Vent # MA00-06401K that you referenced is exhaust only. For a MaxxAir MaxxFan that has the dual functions of exhausting air or pulling the air in in we have part # MA00-06200K or part # MA00-07500K. The big difference between these 2 models is that part # MA00-07500K comes with a remote that you can use to activate the different functions while part # MA00-06200K has a flush mounted keypad instead. I have attached review videos on all 3 fans for you to check...
    view full answer...

  • What is the Difference Between the MaxxAir and Camco RV Vent Covers
  • Both the MaxxAir Standard RV and Trailer Roof Vent Cover part # MA00-933066 and the Camco RV and Enclosed Trailer Roof Vent Cover w/ Detachable Louvered Screen part # CAM40431 are designed to fit 14" x 14" roof vents. The overall dimensions of the MaxxAir is 19" long x 18-1/2" wide x 9-1/2" tall and the overall dimension of the Camco RV is 18-1/2" long x 18" wide x 9-1/2" tall. Both of these roof vent covers come with mounting hardware and have a removable louvered vent for easy cleaning....
    view full answer...

  • Troubleshooting MaxxAir Vent Fan that Won't Turn On and Rain Sensor Light On
  • I spoke with my contact at MaxxAir regarding your vent like the MaxxFan # MA00-04500K. He said what you are experiencing might be caused by a short in the rain sensor. Since that light is coming off and on, this is likely the issue and what is also causing the fan not to turn on. He recommended taking a rag with some rubbing alcohol and simply cleaning out this sensor. Hopefully once it is cleaned out, everything should start working again as normal. If you are still having issues,...
    view full answer...

  • Recommended Vent Fan for Truck Cap to Allow Ventilation for Dogs
  • The MaxxAir MaxxFan Plus - Smoke # MA00-04500K will work on your fiberglass truck cap, but highway speeds will not allow it to stay open. The remote will work fine from inside you truck cab. If you want to be able to drive the highway speeds, I recommend the MaxxFan Deluxe Roof Vent w/ 12V Fan, Thermostat, and Remote - Powered Lift - 10 Speed - Smoke # MA00-07500K. This will keep your dogs safe as long as you have the 12V power on even when you are away from your vehicle. This will...
    view full answer...

  • Wire Size Used to Install MaxxFan Deluxe Roof Vent w/12V Fan & Thermostat MA00-05100K
  • The MaxxFan Deluxe Roof Vent w/ 12V Fan and Thermostat - Manual Lift - 10 Speed - White Item # MA00-05100K only requires 12 volt, 5 amp power to operate so based on this 12 gauge wire would be overkill but 16 gauge such as # DW02359-1 sold by the foot is more ideal.
    view full answer...

  • Troubleshootinng MaxxFan Roof Vent that Keeps Beeping
  • Are you having issues with a MaxxAir MaxxFan roof vent like # MA00-04000K? It could be an internal issue with the fan and it needs to be replaced. Before replacing you can check a couple of things. Is it a new install? If so make sure you have the wiring correct and not reversed. The white wire should be grounded and black to 12 volt power. If the wiring is correct make sure it's getting sufficient power and the connections are good. If both of these check out you likely have...
    view full answer...

  • Which is Quieter the MaxxAir Trailer Roof Vent or the Fan-Tastic Vent Roof Vent
  • The MaxxAir vent # MA00-06401K and the Fan-Tastic Vent roof vent # FV801250 will be close to the same decibel level when running but I give a slight edge to the MaxxAir because it moves a little less air (900 cubic feet per minute versus 920 on the Fan-Tastic) and because it has a sealed ball bearing 12 volt motor which would theoretically be quieter. Honestly you may not be able to tell the difference. As far as wind noise on the exterior I would go with the MaxxAir vent again since...
    view full answer...

  • Replacement Shroud for Coleman-Mach Mach 1 Air Conditioner
  • We do have the MaxxAir TuffMaxx Replacement Shroud # MA00-325001 available, which is designed to replace the shroud on the Coleman-Mach Mach 1 model AC units like what you have. I have also attached an image with the dimensions labeled for this shroud so you can compare them to your existing cover to confirm that it will work well.
    view full answer...

  • How To Add Power Wire for MaxxFan Deluxe Vent with Fan
  • The MaxxFan Deluxe Roof Vent w/ 12V Fan, Thermostat, and Remote - Powered Lift - 10 Speed - Smoke # MA00-07500K requires 12V power at 5 amp draw. Since you are installing in a location that doesn't have power wires run, you will need to run a power wire like # 12-1-1 or # 10-1-1 (sold by the foot) to your battery or to another 12V power source that can handle that draw. There is a good chance the bathroom fan or a light could be a good tie in point as long as you tie in prior to a switch. You...
    view full answer...

  • Replacement A/C Shroud for Older Coleman-Mach 8330 Series A/C Unit on 1999 Exiss Horse Trailer
  • The MaxxAir TuffMaxx Replacement Shroud # MA00-325001 that you referenced will work well on your horse trailer's A/C unit. I spoke with my contact at MaxxAir and Coleman-Mach and confirmed the replacement shroud will fit your unit. Based on my research, your model number 8333-871 is an older model Coleman-Mach air conditioning unit. The current model number that corresponds with your unit's model number is 48203C966. This model number is a Mach 3 Plus unit.
    view full answer...

  • Replacement Air Conditioner Shroud Housing for Coleman Mach Model 8335-896
  • Absolutely! The shroud that fits your Coleman unit is the MaxxAir TuffMaxx Replacement Shroud # MA00-325001.
    view full answer...

  • Dimensions of MaxxFan Deluxe Roof Vent MA00-07500K
  • You are correct that the MaxxFan Deluxe Roof Vent # MA00-07500K fits a standard 14 x 14-inch RV roof opening. The actual mounting flange measures 16-1/2 x 16-1/2. The overall dimensions for the vent are 22-1/2 long x 16-1/2 wide x 5-inches tall. You may also care to refer to the two linked videos on this item.
    view full answer...

  • How Much Amperage Does the MaxxAir MaxxFan # MA00-07500K Draw
  • The 900 CFM fan of the MaxxAir MaxxFan # MA00-07500K that you referenced needs to be attached to at least a 5 amp circuit.
    view full answer...

  • Air Conditioner Shroud Recommendation for Coleman TSR Air Conditioner Unit
  • From previous customers with a Coleman TSR air conditioner that gave us dimensions we have the MaxxAir TuffMaxx Replacement Shroud # MA00-325001 that we've been able to confirm as a fit.
    view full answer...

  • Can the Rain Sensor on a MaxxAir Vent be Overridden
  • MaxxAir vents that have an integrated rain sensor, like the MaxxFan Plus Roof Vent # MA00-04500K, do not allow you to override the sensor. If you were to override it you would be allowing rain to hit the motor which could definitely damage it. The sensor will close the lid and shut off the fan when it is wet, but when it dries up the vent will open up and turn the fan back on.
    view full answer...

  • Can MaxxFan Deluxe Roof Vent # MA00-07500K be Wired Directly to Battery
  • There is no reason why you cannot power your MaxxFan Deluxe Roof Vent # MA00-07500K from your battery using a 12-Volt DC Outlet # HM55115. You will then just need a plug for the socket, like the part # A-200, which is rated properly for your power application. You may want to install a 10 amp fuse with a Fuse Holder # SWC9538 as well to help protect the circuit.
    view full answer...

  • Coleman Mach Air Conditioner Replacement Shroud to Cover Rooftop Unit
  • The the MaxxAir shroud part # MA00-325001 is a fit for the Coleman Mach, Mach 1, Mach 3 and Mach 15 models and mounts like the original and includes mounting hardware and instructions. Mach is an entire model line of Coleman air conditioners and Mach 1 is the original, so Mach and Mach 1 are the same. Then it jumps to Mach 3, 8, and 15. These models all will use the same replacement shroud.
    view full answer...

  • Can Maxxair MA00-06401K Vent Be Left Open While Traveling at Highway Speeds?
  • I reached out to my tech contact at MaxxFan and confirmed the MaxxFan Deluxe Roof Vent w/ 12V Fan - Manual Lift - 4 Speed - Smoke # MA00-06401K can be left open while traveling at highway speeds. You won't need to have the cover like the more traditional vent to allow that because the design of the unit accounts for it when installed correctly.
    view full answer...

  • Hardware Needed to Install MaxxFan Deluxe Roof Vent # MA00-05100K
  • The MaxxFan Deluxe Roof Vent w/ 12V Fan and Thermostat # MA00-05100K referenced in your question includes the white interior trim piece (garnish), insulated electrical connectors and the hardware needed for installation. The only thing you will need to add is some roof sealant # 0160297 and 16 gauge wire like # DW02359-1 if you don't already have it. The wire is sold by the foot so you can get exactly the length you need. This is a really nice roof vent with fan that will move air in...
    view full answer...

  • Replacement Shroud for Coleman RVP Roof Air Conditioning Unit Needed
  • We do have some different air conditioner shrouds available which I have linked our selection to this page for you to filter through. I tried looking up the dimensions online but was unable to come up with anything. I recommend taking a look at the MaxxAir TuffMaxx Replacement Shroud # MA00-325001 which is 41-5/8" long x 28-3/4" wide at the base, is 12-5/8" high, and measures 21" long x 17-13/16" wide at the top (see attached picture). You will want to measure your Coleman AC unit to...
    view full answer...

  • Troubleshooting a MaxxFan Roof Vent Fan That Has Stopped Working
  • Roof vents with fans like the MaxxFan Roof Vent w/ 12V Fan # MA00-04000K do not have a fuse anywhere in the fan itself. You will want to use a circuit tester like # PTW2993 to see if there is power getting to the fan. If it was installed by the manufacturer, there may be a circuit breaker that it is attached to, but most of the time they are directly wired to the 12V power. If there is power going to the switch, you may simply need to replace the switch and not the entire assembly....
    view full answer...

  • How Do You Remove The Screen On the MaxxAir MaxxFan?
  • To remove the screen for the MaxxAir MaxxFan Trailer Roof Vent w/ 12V Fan - Manual Lift - 14-1/4" x 14-1/4" - White, # MA00-04000K, you simply remove it from the 4 mounting tabs. These tabs rotate. I've attached a picture for you.
    view full answer...

  • Difference Between MaxxAir Mini Deluxe Roof Vents # MA00-03851 and # MA00-03801
  • The MaxxAir Mini Deluxe Trailer Roof Vent w/ 12V Fan - Black # MA00-03851 and the MaxxAir Mini Deluxe - White # MA00-03801 that you referenced are indeed identical units except for their lid color. Both are 12V DC powered exhaust fans with 1 speed option and feature an integrated rain shield to prevent water from entering the RV or trailer. Any difference in price between the two options is simply related to manufacturer pricing and supply and demand. I have attached a video demonstration...
    view full answer...

  • Replacement AC Shroud for Coleman Mach Air Conditioner
  • We do have replacement AC shrouds for your Coleman Mach Unit. You will want the MaxxAir TuffMaxx Replacement Shroud - White # MA00-325001 which is a confirmed fit for your AC unit. While you are replacing this, I also recommend you add the Start Capacitor for Advent Air RV Air Conditioners # ACMSCKIT which will allow your AC to start without requiring extra amperage, so it will start the first time and every time you need it by storing the energy needed for that start power draw.
    view full answer...

  • Power Requirements of the MaxxFan Deluxe Roof Vent w/ 12V Fan and Thermostat # MA00-05100K
  • The MaxxFan Deluxe Roof Vent w/ 12V Fan and Thermostat # MA00-05100K that you referenced runs on 12 volts and draws 5 amps max. If your DC outlet can handle 5 amps then this would work but it would be right at the limit.
    view full answer...

  • How Tall is the MaxxAir MaxxFan Deluxe # MA00-05301K
  • When the MaxxAir MaxxFan Deluxe # MA00-05301K is in the open position it sits above the roof 9-5/16" but when it is in the closed position it sits above the roof only 5". If you check out the linked review video our team member mentions this at about the 4:00 mark.
    view full answer...

  • Is Butyl Tape Needed When Installing MaxFan Roof Vent
  • When installing the MaxxFan Roof Vent # MA00A04301K that you referenced you will want to use butyl tape on the vent edges in addition to the sealant that you will apply around the unit to cover up bolt holes and any other areas that might lead to a leak. I have attached a sample vent installation on a different model vent just so you can get a better idea of the process. We do have the Roof Vent Installation Kit # 344270KITW available that includes a 10.1 oz bottle of sealant, a 60...
    view full answer...